Abstract
A technical failure in a gas pipeline represents an event with a significant impact on the safety and operation of the natural gas transmission system. The analysis and assessment of such a failure are essential for identifying the causes, limiting the effects, and preventing similar incidents in the future. Gas pipelines are part of the critical infrastructure of the Romanian Gas System, and any malfunction can affect the gas supply to both industrial and residential consumers. The process of analyzing a failure begins with identifying the type of defect and the circumstances under which it occurred. Common causes include pipeline corrosion, material defects, construction or installation errors, excessive pressures within the system, or unauthorized external interventions affecting the infrastructure. Technical evaluation involves inspecting the affected area, using diagnostic methods such as non-destructive testing, analyzing pressure and flow data, and reviewing the pipeline’s maintenance history. The impact on the operation of the Romanian Gas System may vary depending on the severity of the failure and the position of the pipeline within the network. In the case of a main pipeline, the failure may lead to a reduction in system pressure, temporary interruption of supply to certain regions, or the need to redistribute gas flows through alternative routes. These measures can involve high operational costs and may affect the stability of energy supply. Furthermore, a failure may generate additional risks for the environment and public safety, especially if there are gas leaks or a risk of explosion. For this reason, the rapid intervention of specialized teams and the application of safety procedures are essential in order to limit the consequences. Following the technical analysis, an evaluation report is prepared, including the causes of the failure, the remedial measures taken, and recommendations to prevent similar situations. The implementation of rigorous monitoring programs, preventive maintenance, and infrastructure modernization contributes to increasing the safety and reliability of the Romanian Gas System in the long term.
Cuvinte cheie
Analysis
Assessment
technical failure
Gas system
Istoric articol
Publicat
01.04.2026
Informații autori
Citare recomandată
Adina TĂTAR, Ioan Lucian DIODIU, Adriana ZAMORA, Sorina Daniela STĂNILĂ, Florin MURESAN – GRECU, Adrian Mihai SCHIOPU, Daria IONESCU (2026). Analysis And Assessment of a Technical Failure in A Gas Pipeline and Its Impact on The Operation of The Romanian Gas System. Journal of Fiability and Durability, 1(1), 311–320. https://doi.org/10.65631/JFD.1(37).2026.37
Referințe bibliografice
[1]. Daniel Fîță, Sorin Mihai Radu, Marcela Draghilă, Antonia Obreja, Ioan Sima, Cristian Sigheartău, Alin Cruceru, Alexandru Radu, Geopolitică, Relații internaționale, Studii de securitate, Editura Risoprint Cluj Napoca, ISBN: 978-973-53-3386-7, 2025.
[2]. Fîță, N.D.; Pasculescu D,; Dragoș, P.; Ilieva, O.M.; Gabriel, P.F.; Teodora, L.; Alin, C.E.; Cristian, L.D.; Gabriela, S.; Eugen, S.G.; Mihai, Ș.A. Vulnerability and Risk Management to Ensure the Occupational Safety of Underground Mines. Eng 2025, 6, 88. doi: 10.3390/eng6050088, 20
[3]. Pasculescu Dragos, Niculescu Titu, Pana Leon, "Uses of Matlab software to size intrinsic safety barriers of the electric equipment intended for use in atmospheres with explosion hazard", International Conference on Energy and Environment Technologies and Equipment (EEETE'10),“Politehnica” University, Bucharest, Romania Published by WSEAS Press ISSN. Vol. 5095. 1790, 2010.
[4]. Arad Susana, et al. "Aspects of the electric arc furnace control", Proceedings of the International Symposium on Advanced Engineering & Applied Management, Hunedoara, Romania, 2010.
[5]. Riurean Simona, Fîță Nicolae Daniel, Păsculescu Dragos, Slușariuc Razvan, Securing Photovoltaic Systems as Critical Infrastructure: A Multi-Layered Assessment of Risk, Safety, and Cybersecurity, Sustainability, 17(10), 4397, 2025.
[6]. Pasculescu, D., Riurean, S., Ilieva-Obretenova, M., Lazar, T., Tatar, A. M., & Fita, N. D., Intelligent modeling of PV–BESS microgrids for enhanced stability, cyber–physical resilience and blackout prevention, Energies, 19(1), 148, 2026.